The optimal prevention strategy is not currently known. To assess current CMV prevention practices, a web-based survey was conducted within the North American Studies in Pediatric Liver Transplantation (SPLIT) network. Twenty-nine of the 31 centers (94%) surveyed responded. Only seven centers reported evidence-based development of protocols.
For most at-risk (donor or recipient CMV seropositive) PLT recipients, a prophylactic strategy predominates current practice. For high-risk (D+/R-), only three centers used non-prophylaxis-based protocols: one preemptive and two sequential/hybrid. Duration of prophylaxis ranged from 84 to 730 days with 14 centers using around 100 days and nine centers using around 200 days. Initial therapy with ganciclovir followed by valganciclovir was the most selleck chemicals llc common strategy. For lower-risk recipients (CMV D-/R-), more centers (10/29) employed a preemptive strategy while the remainder described prophylaxis (15)
and sequential/hybrid (3) strategies. Prophylaxis predominates current CMV prevention strategies for at-risk recipients within SPLIT. The variation in duration of therapy provides the opportunity to perform comparative effectiveness studies within SPLIT.”
“A study was conducted to detect and quantify lard stearin (LS) content in canola oil (CaO) using differential scanning calorimetry this website (DSC). Authentic samples of CaO were obtained from a reliable supplier and the adulterant LS were obtained through a fractional crystallization procedure as reported previously. Pure CaO samples spiked with LS in levels ranging from 5 to 15% (w/w) were analyzed using DSC HM781-36B to obtain their cooling and heating profiles. The results showed that samples contaminated with LS at 5% (w/w) level can be detected using characteristic contaminant peaks appearing in the higher temperature regions (0 to 70 degrees C) of the cooling and heating curves. Pearson correlation analysis of LS content against individual DSC parameters of the adulterant peak namely peak temperature, peak area, peak onset temperature indicated
that there were strong correlations between these with the LS content of the CaO admixtures. When these three parameters were engaged as variables in the execution of the stepwise regression procedure, predictive models for determination of LS content in CaO were obtained. The predictive models obtained with single DSC parameter had relatively lower coefficient of determination (R-2 value) and higher standard error than the models obtained using two DSC parameters in combination. This study concluded that the predictive models obtained with peak area and peak onset temperature of the adulteration peak would be more accurate for prediction of LS content in CaO based on the highest coefficient of determination (R-2 value) and smallest standard error.